Product Description
How to set the controller?
1. Set the start temperature:
Press Up button show the starting temperature;
long press UP button the temperature display Flashing , press the UP or Down button to set the start temperature value.
2. Set the stop temperature:
Press Down button show the Stop temperature;
long press Down button the temperature display Flashing , press the UP or Down button to set the stop temperature value.
3. Restore factory settings:
Long press the Up and Down bottons when the controller is powered, the display shows "888" and switch to detection temperature.
Product Parameters
| Model |
XH-W3001 |
| Input power |
AC 220V DC 12V DC 24V (Optional) |
| Temperature measurement range |
- 50 ~ 110°C |
| Temperature control range |
- 50 ~ 110°C |
| Temperature measuring accuracy |
±0.2 °C |
| Temperature control precision |
±0.1 °C |
| Measuring input |
NTC10K, 1 meters long waterproof probe |
| Output Type |
Direct Output |
| Output Capacity |
Max 10A AC 220V or DC 12v 24v |
| Appearance size |
60 * 45 * 31 mm |
Details Images




Introduction to code and features
PO setting start temperature
Press the Setup button to enter the internal menu. The default display is PO. Press the Setup button again to set the required startup temperature with the up and down buttons.
P1 sets the stop temperature
Press the setup button to enter the internal menu, the display is P0, switch to P1 by the up and down keys, press the setup button again, and set the required stop temperature by the up and down buttons.
P2 set temperature correction
In the same way, enter the internal menu, switch to P2 by pressing the up and down buttons, press the setting button again, and set the required calibration temperature by the up and down buttons. (Note: In the setting, if the detected temperature value is 0.5c larger than the actual temperature value, then the calibration temperature to be set is -0.5'C. If the detected value is 1'C smaller than the actual temperature value, the calibration temperature to be set is 1 'C, detection temperature + corrected temperature = actual temperature.)
P3 set delay start
In the same way, enter the internal menu, switch to P3 by pressing the up and down buttons, press the setting button again, and set the required delay time by the up and down buttons, the unit is minute. (Note: Delay start is generally used for compressor refrigeration. If it is used in refrigerator freezer, this value needs to be set. According to compressor back pressure, the general setting is 3-6 points, if you are not using it for control or No delay function is required, skip it directly.
Note: The appearance of the product may vary somewhat depending on the production lot. But the performance is the same.
Detailed Photos