HY525 wired master control panel is used to control water pump, Boiler, thermal actuator, motorised valve etc. HY525- Hub Controllers is used in water underfloor heating system. It can control zone valves, or boiler thermostats. As central control unit, it can also control boiler and circulating pump. According to user's set temperature, hub controller can control to open or close boiler, circulating pump and electric actuators, to achieve the purpose of comfort and energy consumption saving.
Material
|
Anti-flammable PC +ABS
|
Model Number
|
HY525
|
Relay output max current
|
3A
|
Size
|
240*110*42 mm
|
Storage temp
|
-20ºC ~ 70ºC
|
Ambient temp
|
-20ºC ~ 60ºC
|
Color
|
Whtie
|
Power
|
170-240VAC50/60Hz
|
Control accuracy
|
±1°C
|
Power consumption
|
<10W
|
Delay time
|
60s
|
1. Easy to connect with power:
user only needs to reserve main supply in the place of manifold before installation, and directly connect one three-wires cable to thermostats. So user do not need professional wiring workers;
2. Easy to connect wires:
User only needs to connect wires according to wire colors;
3. Easy maintenance after installation:
All wires are very clear and neat;
4. To protect boiler or pump:
Hub controller has time delay function, it opens boiler and pump only when water valve is totally opened, and closes boiler when temperature reaches requirements. Time delay to open boiler and pump when heating can realize the purpose of energy-saving;
5. To extend boiler and pump life:
Hub controller only start boiler and pump in appropriate temperature, in this way, it will reduce boiler and pump running time, to extend their working life.
Before Using:
If you need to debug or check whether the master controller is working normally, you can press and hold the debug button before powering on and then power on. At this time, the time delay is invalid, you can quickly check the functions required for debugging (such as the debugging function after 20 minutes of no operation). Invalid).
The working time required for the delay time can be adjusted by the dial switch, and can be adjusted according to the product indication position scheme.
Notes:
1,Please cut off power before installation, cleaning or replace
2,Please read manual carefully before installation and operation
3,Suggest let the professional worker install